OBJECTIVE: For this challenge, we have created two versions of the mixing tee. One of them is longer than the other. Our job is to set up steady-state simulations to compare the mixing effectiveness when hot inlet temperature is 360C & the Cold inlet is at 190C.  Use the k-epsilon and k-omega SST model for the…

  • CFD
  • Sachin Barse

    updated on 07 Nov 2022

OBJECTIVE:

For this challenge, we have created two versions of the mixing tee. One of them is longer than the other.

Our job is to set up steady-state simulations to compare the mixing effectiveness when hot inlet temperature is 360C & the Cold inlet is at 190C. 

Use the k-epsilon and k-omega SST model for the first case and based on your judgment use the more suitable model for further cases. Giving the reason for choosing a suitable model is compulsory. 

  1. Case 1 
    • Short mixing tee with a hot inlet velocity of 3m/s.
    • Momentum ratio of 2, 4. 
  2. Case 2 
    • Long mixing tee with a hot inlet velocity of 3m/s.
    • Momentum ratio of 2, 4.

INTRODUCTION:

The function of mixing Tee is to provide proper mixing of quantities to get the desired result at the outlet.

 

By controlling the velocity of chilled air we can get the desired temperature in the room.

ANSYS WORKFLOW:

 

GEOMETRY: Construct a two or three dimensional representation of the object to be modelled and tested using the work plane coordinate system within ANSYS.

MESH: At this point ANSYS understands the makeup of the part. Now define how the modelled system should be broken down into finite pieces.

SETUP: The case setup will be done using ansys fluent

SOLUTION: Ansys fluent where run time result visualization is done

RESULTS: Post processing of results will be done here using CFD-post

SHORT TEE:

GEOMETRY SETUP:

The computational models are uploaded to the Ansys Space Claim as a step file.

In this project, we are interested in performing fluid flow analysis through the geometry, hence we used the volume extraction option to extract the fluid volume from the geometry. Then the solid model is suppressed for physics from the fluid model to create mesh at the interested region.

MESH GENERATION:

The boundary names inlet_x, inlet_y, outlet and wall are defined using the named selection option.

After generating the mesh, the number of nodes and elements are investigated using the statistics option. Then the mesh quality is checked by choosing the mesh metrices option in quality section.

The element quality should not be less than 5%. In our case minimum mesh quality is 30%, so we can move ahead.

SETUP AND SOLUTION:

CASE 1:

  • Short mixing Tee with a hot inlet velocity of 3m/s
  • Momentum ratio of 2,4

CASE 1.1:

  • Short mixing Tee with a hot inlet velocity of 3m/s
  • Momentum ratio of 2

SETUPS

 

SHORT TEE (MR=2 AND HOT INLET VELOCITY = 3m/s)

 

K-EPSILON

K-OMEGA

SOLVER TYPE

Pressure based

Pressure based

VELOCITY FORMULATION

Absolute

Absolute

TIME

Steady

Steady

VISCOUS MODEL

Realizable K-epsilon with standard wall function

K-omega SST model

MATERIAL

Air

Air

CELL ZONES

Fluid type : air

Fluid type : air

BOUNDARIES

·       Inlet_x (velocity inlet)

        Velocity magnitude 3m/s

        Temperature  - 360c

·       Inlet_y (velocity inlet)

        Velocity magnitude 6m/s

        Temperature – 190c

·       Outlet (pressure outlet)

        Gauge pressure – 0 pa

·       Walls – stationary   walls

·       Inlet_x (velocity inlet)

        Velocity magnitude 3m/s

        Temperature  - 360c

·       Inlet_y (velocity inlet)

        Velocity magnitude 6m/s

        Temperature – 190c

·       Outlet (pressure outlet)

        Gauge pressure – 0 pa

·       Walls – stationary   walls

 

The hybrid scheme is used for initialization and the no. of iterations are setup and then click on calculate option.

RESULTS:

K-EPSILON MODEL:

RESIDUAL PLOT:

AREA WEIGHTED AVERAGE:

STANDARD DEVIATION:

CONTOUR PLOT:

TEMPERATURE CONTOUR:

VELOCITY CONTOUR:

STREAMLINE PLOT:

TEMPERATURE:

VELOCITY:

K-OMEGA MODEL:

RESIDUAL PLOT:

AREA WEIGHTED AVERAGE:

STANDARD DEVIATION:

CONTOUR PLOT:

TEMPERATURE CONTOUR:

VELOCITY CONTOUR:

STREAMLINE PLOT:

TEMPERATURE:

VELOCITY:

SUMMARY:

 

SHORT TEE (MR = 2)

K-EPSILON

K-OMEGA

AVERAGE OUTLET TEMPERATURE [K]

303.413

303.458

STANDARD DEVIATION

1.5

1.6

NO OF ITERATIONS

150

170

 

CASE 1.2:

  • Short mixing Tee with a hot inlet velocity of 3m/s
  • Momentum ratio of 4

SETUPS

 

SHORT TEE (MR=2 AND HOT INLET VELOCITY = 3m/s)

 

K-EPSILON

K-OMEGA

SOLVER TYPE

Pressure based

Pressure based

VELOCITY FORMULATION

Absolute

Absolute

TIME

Steady

Steady

VISCOUS MODEL

Realizable K-epsilon with standard wall function

K-omega SST model

MATERIAL

Air

Air

CELL ZONES

Fluid type : air

Fluid type : air

BOUNDARIES

·       Inlet_x (velocity inlet)

        Velocity magnitude 3m/s

        Temperature  - 360c

·       Inlet_y (velocity inlet)

        Velocity magnitude 12m/s

        Temperature – 190c

·       Outlet (pressure outlet)

        Gauge pressure – 0 pa

·       Walls – stationary   walls

·       Inlet_x (velocity inlet)

        Velocity magnitude 3m/s

        Temperature  - 360c

·       Inlet_y (velocity inlet)

        Velocity magnitude 12m/s

        Temperature – 190c

·       Outlet (pressure outlet)

        Gauge pressure – 0 pa

·       Walls – stationary   walls

 

The hybrid scheme is used for initialization and the no. of iterations are setup and then click on calculate option.

RESULTS:

K-EPSILON MODEL:

RESIDUAL PLOT:

AREA WEIGHTED AVERAGE:

STANDARD DEVIATION:

CONTOUR PLOT:

TEMPERATURE CONTOUR:

VELOCITY CONTOUR:

STREAMLINE PLOT:

TEMPERATURE:

VELOCITY:

K-OMEGA MODEL:

RESIDUAL PLOT:

AREA WEIGHTED AVERAGE:

STANDARD DEVIATION:

CONTOUR PLOT:

TEMPERATURE CONTOUR:

VELOCITY CONTOUR:

STREAMLINE PLOT:

TEMPERATURE:

VELOCITY:

SUMMARY:

 

SHORT TEE (MR = 4)

K-EPSILON

K-OMEGA

AVERAGE OUTLET TEMPERATURE [K]

300.396

300.38

STANDARD DEVIATION

1.1

1.2

NO OF ITERATIONS

130

160

 

ANALYTICAL SOLUTION:

MOMENTUM RATIO 2:

  • Mass of hot fluid (mh) = rho*a*Vh = 997*0.0009*3 = 2.69 kg/s
  • Mass of cold fluid (mc) = rho*a*Vc = 997*0.0009*6 = 1.35 kg/s
  • Temperature of mixture (Tmixture) = (mh*Th + mc*Tc)/(mc + mh) = 30.3190c = 303.319k

MOMENTUM RATIO 4:

  • Mass of hot fluid (mh) = rho*a*Vh = 997*0.0009*3 = 2.69 kg/s
  • Mass of cold fluid (mc) = rho*a*Vc = 997*0.0009*12 = 2.3928 kg/s
  • Temperature of mixture (Tmixture) = (mh*Th + mc*Tc)/(mc + mh) = 27.990c = 300.99k

CONCLUSION:

AVERAGE OUTLET TEMPERATURE:

On comparing the both models with analytical solution we got nearly the same results.

ITERATIONS TO CONVERGE:

No. of iterations taken to converge is less for Realisable K-epsilon model than K-omega SST model.

STANDARD DEVIATION:

The standard deviation of k-epsilon model is less than k-omega model which shows the better mixing efficiency in k-epsilon model.

So based on the above observations the K-epsilon turbulence model is predicting the results accurately in less no. of iterations. So we can use realisable k-epsilon model for case 2

LONG TEE:

GEOMETRY SETUP:

The computational models are uploaded to the Ansys Space Claim as a step file.

In this project, we are interested in performing fluid flow analysis through the geometry, hence we used the volume extraction option to extract the fluid volume from the geometry. Then the solid model is suppressed for physics from the fluid model to create mesh at the interested region.

MESH GENERATION:

The boundary names inlet_x, inlet_y, outlet and wall are defined using the named selection option.

After generating the mesh, the number of nodes and elements are investigated using the statistics option. Then the mesh quality is checked by choosing the mesh metrices option in quality section.

The element quality should not be less than 5%. In our case minimum mesh quality is 30%, so we can move ahead.

SETUP AND SOLUTION:

CASE 2:

  • Long mixing tee with a hot inlet velocity of 3m/s.
  • Momentum ratio of 2, 4.

CASE 2.1:

  • Long mixing tee with a hot inlet velocity of 3m/s.
  • Momentum ratio of 2.

SETUPS

LONG TEE (MR=2 AND HOT INLET VELOCITY 3m/s)

K-EPSILON

SOLVER TYPE

Pressure based

VELOCITY FORMULATION

Absolute

TIME

Steady

VISCOUS MODEL

Realizable K-epsilon with standard wall function

MATERIAL

Air

CELL ZONES

Fluid type : air

BOUNDARIES

·       Inlet_x (velocity inlet)

        Velocity magnitude 3m/s

        Temperature  - 360c

·       Inlet_y (velocity inlet)

        Velocity magnitude 6m/s

        Temperature – 190c

·       Outlet (pressure outlet)

        Gauge pressure – 0 pa

·       Walls – stationary   walls

The hybrid scheme is used for initialization and the no. of iterations are setup and then click on calculate option.

RESULTS:

RESIDUAL PLOT:

AREA WEIGHTED AVERAGE:

STANDARD DEVIATION:

CONTOUR PLOT:

TEMPERATURE CONTOUR:

VELOCITY CONTOUR:

STREAMLINE PLOT:

TEMPERATURE:

VELOCITY:

CASE 2.2:

  • Long mixing tee with a hot inlet velocity of 3m/s.
  • Momentum ratio of 4.

SETUPS

LONG TEE (MR=2 AND HOT INLET VELOCITY 3m/s)

K-EPSILON

SOLVER TYPE

Pressure based

VELOCITY FORMULATION

Absolute

TIME

Steady

VISCOUS MODEL

Realizable K-epsilon with standard wall function

MATERIAL

Air

CELL ZONES

Fluid type : air

BOUNDARIES

·       Inlet_x (velocity inlet)

        Velocity magnitude 3m/s

        Temperature  - 360c

·       Inlet_y (velocity inlet)

        Velocity magnitude 12m/s

        Temperature – 190c

·       Outlet (pressure outlet)

        Gauge pressure – 0 pa

·       Walls – stationary   walls

The hybrid scheme is used for initialization and the no. of iterations are setup and then click on calculate option.

RESULTS:

RESIDUAL PLOT:

AREA WEIGHTED AVERAGE:

STANDARD DEVIATION:

CONTOUR PLOT:

TEMPERATURE CONTOUR:

VELOCITY CONTOUR:

STREAMLINE PLOT:

TEMPERATURE:

VELOCITY:

SUMMARY:

 

LONG TEE (MR = 2)

LONG TEE (MR = 4)

AVERAGE OUTLET TEMPERATURE [K]

303.367

300.449

STANDARD DEVIATION

1.2

0.8

NO OF ITERATIONS

180

130

COMPARISON OF BOTH LONG AND SHORT TEE:

K-EPSILON REALIZABLE MODEL

GEOMETRY

MOMENTUM RATIO

CELL COUNT

AVERAGE OUTLET TEMPERATURE [K]

NO. OF ITERATIONS

STANDARD DEVIATION

SHORT TEE

2

12583

303.413

150

1.5

SHORT TEE

4

12583

300.396

130

1.1

LONG TEE

2

15368

303.367

180

1.2

LONG TEE

4

15368

300.449

130

0.8

OVERALL DISCUSSION:

AVERAGE OUTLET TEMPERATURE:

Irrespective of length of the mixing Tee, the average outlet temperature on both cases are quite same.

MOMENTUM RATIO:

  • As momentum ratio increases, the velocity of cold inlet fluid increases and due to high relative velocity between the fluid it experiences higher turbulence and therefore the outlet fluid temperature decreases.
  • For momentum ratio 2, the average outlet fluid temperature is 303k whereas for momentum ratio 4 the average outlet fluid temperature is 300k. From these we can say that there will be a drop in temperature if momentum ratio increases.
  • In order to obtain better mixing the velocity of cold air is important. By increasing the cold fluid velocity the outlet temperature gets reduced.

NO. OF ITERATIONS:

The longer Tee takes more time to converge than short Tee.

CONCLUSION:

  • Higher the momentum ratio, higher will be the mixing efficiency of Tee joint.
  • Increasing the length of the pipe doesn’t serve the purpose of mixing efficiently. So, it is efficient to use short pipe.

GRID INDEPENDENCY TEST:

Short Tee model is selected for grid dependence test.

MESH GENERATION:

5mm:

4mm:

3mm:

RESULTS:

5mm:

RESIDUAL PLOT:


AREA WEIGHTED AVERAGE OF TEMPERATURE:

STANDARD DEVIATION OF TEMPERATURE:

4mm:

RESIDUAL PLOT:

AREA WEIGHTED AVERAGE OF TEMPERATURE:

STANDARD DEVIATION OF TEMPERATURE:

3mm:

RESIDUAL PLOT:

AREA WEIGHTED AVERAGE OF TEMPERATURE:

STANDARD DEVIATION OF TEMPERATURE:

SUMMARY:

MESH SIZE

NO. OF ELEMENTS

NO. OF NODES

AVERAGE OUTLET TEMPERATURE

NO. OF ITERATIONS

5mm

16143

3460

303.251

250

4mm

23007

4925

303.246

175

3mm

39921

8369

303.292

210

 

CONCLUSION:

  • The mesh size of 3mm gives the best predicted results than other two mesh size
  • Decreasing the mesh size, the average outlet temperature starts approaching towards the analytical results.

Leave a comment

Thanks for choosing to leave a comment. Please keep in mind that all the comments are moderated as per our comment policy, and your email will not be published for privacy reasons. Please leave a personal & meaningful conversation.

Please  login to add a comment

Other comments...

No comments yet!
Be the first to add a comment

Read more Projects by Sachin Barse (93)

FINAL INDEPENDENT PROJECT

Objective:

Project : Design & Animate the drone camera for project model.   Attached Link For Model Review :  https://drive.google.com/file/d/1f6sjaJc6Od2AEnmh-JYFFoLMmUveWk61/view?usp=drive_link

calendar

15 May 2024 05:42 PM IST

    Read more

    Week - 4

    Objective:

    AIM:      Implement control logic of a “washing machine” using Stateflow as per given sequence:  If the power supply is available, the system gets activated. If the Water supply is not available, stop the process & indicate through LED Soaking time should be 200s followed by Washing…

    calendar

    13 Mar 2024 10:27 AM IST

      Read more

      Week -2

      Objective:

      1.Door Bell Simulink Model: Simulink Model Explanation: The pulse generator is used to create square wave pulses at regular intervals.The block waveform parameters Amplitude,pulse width,period and phase delay,determine the shape of the output waveform.                    …

      calendar

      12 Mar 2024 12:23 PM IST

        Read more

        Project 1

        Objective:

        Attached Model for Project :- Attached link for grading :- https://drive.google.com/file/d/13bjiEKi2h1sYtm9LzZMouMksFAZYnVIQ/view?usp=drive_link

        calendar

        29 Oct 2023 11:00 AM IST

          Read more

          Schedule a counselling session

          Please enter your name
          Please enter a valid email
          Please enter a valid number

          Related Courses

          coursecardcoursetype

          Post Graduate Program in CFD Solver Development

          4.8

          119 Hours of Content

          coursecard

          Introduction to OpenFOAM Development

          4.9

          18 Hours of Content

          coursecardcoursetype

          Post Graduate Program in Battery Technology for Mechanical Engineers

          4.8

          81 Hours of Content

          coursecardcoursetype

          Post Graduate Program in Automation & Pre-Processing for FEA & CFD Analysis

          4.7

          81 Hours of Content

          coursecardcoursetype

          Post Graduate Program in Hybrid Electric Vehicle Design and Analysis

          4.8

          343 Hours of Content

          Schedule a counselling session

          Please enter your name
          Please enter a valid email
          Please enter a valid number

                      Do You Want To Showcase Your Technical Skills?
                      Sign-Up for our projects.