To calculate wind load for industrial steel structures and to apply it by using TSD

1) Aim - Generate manual wind loading in the design report based IS code as per the following input Basic wind speed = 39 m/s Terrain category = 2 Procedure - First calculate load combination  Result - Calculations are done for the wall panel   2) Aim - Based on the above calculation apply the loading on the model Procedure…

    • Md Sameer

      updated on 03 Oct 2023

    1)

    Aim - Generate manual wind loading in the design report based IS code as per the following input

    Basic wind speed = 39 m/s

    Terrain category = 2

    Procedure -

    First calculate load combination 

    Result - Calculations are done for the wall panel

     

    2)

    Aim - Based on the above calculation apply the loading on the model

    Procedure -

    • Open tekla structural software and open week 4 file
    • Select load tab, in that select loadcases and add new load cases

     

    • Now as per value apply the load
    • Frame 1 = Wind+y+cpi = 0.253 kn/m^2

     

    • Apply load on Frame 5 = Wind +y+cpi = -0.951 kn/m^2
    • Negative value means wind acting away from the wind panel

     

    • Apply load on face 1 = wind+y-cpi = 1.52 kn/m^2

     

    • Apply load on face 5 = wind+y-cpi =0.317 kn/m62

    • Apply load on face C =wind+y+cpi = -1.394 kn/m^2

     

    • Apply load on face D=wind+y-cpi = -0.127 kn/m^2

     

    • Now we will apply load of -y
    • All loading will be similar just the direction of wind is changed
    • Frame 5 = wind-y+cpi = -0.253 kn/m^2

     

    • Apply load on Frame 1 - wind-y+cpi = 0.951 kn/m^2

     

    • Apply load on Frame 5 = wind-y-cpi = -1.521 kn/m^2

     

    • Apply load on Frame 1 = wind-y-cpi = -0.317 kn/m^2

     

    • Apply load on frame D = wind-y+cpi = 1.394kn/m^2 on global X axis

     

    • Apply load on frame A=wind-y-cpi = 0.127 kn/m^2 on global X axis

     

    • Apply load on face C = wind+y-cpi = 0.317kn/m^2

     

     

    • Now apply wind load on roofs and take roof angle as 25 degree
    • From IS 875 part  3 table 3 clause 6.2.3.2 
    • Now apply roof load on  PQ
    • Frame 2 =wind+y+cpi = -1.204 kn/m^2

     

    • Apply load on frame 2= wind+y-cpi = 0.063kn/m^2

    FAQ

     

    FAQ

     

     

    • Roof XY
    • Apply load on frame 1 =wind+y-cpi = 0 kn/m^2

     

    • Roof PQ
    • Apply load on frame 1=wind-y+cpi = 1.204kn/m^2

     

    • Apply load on frame 1=wind-y-cpi= =0.063 kn/m^2 on roof PR

     

    • Apply load on frame 2 of roof XY = wind -y+cpi = 1.267 kn/m^2

     

    • Apply 0 kn/m^2 on roof XY of frame 2  

    Result -

     

    3)

    Aim - On a separate model generate wind loading using wind wizard

    Procedure -

    • Open the file
    • Open load cases in load tab
    • Delete all load cases and set only default load cases

     

    • On load panel select wind wizard and select the cyclonic effect

     

    • Check all the details of the building like wind speed,height of building affected by wind and also k1 and k2 factor

     

    • Select terrain category as open terrain scattered obstructions
    • Fetch distance is 10

     

    • Click next then select topography and then next
    • After that,it shows resultant wind pressure 

    • Click on Finish 
    • Now click on wind load cases

    • Now all the loads are applied.and click on validation to check for errors.

    Result - 

     

    Leave a comment

    Thanks for choosing to leave a comment. Please keep in mind that all the comments are moderated as per our comment policy, and your email will not be published for privacy reasons. Please leave a personal & meaningful conversation.

    Please  login to add a comment

    Other comments...

    No comments yet!
    Be the first to add a comment

    Read more Projects by Md Sameer (55)

    Project 1 - MODELLING, ANALYSIS & DESIGN OF TALL BUILDINGS IN ETABS

    Objective:

    Question. A 30 - 40hr project on modelling, analysis & design of a state-of-the-art tall building using ETABS software.Key Highlights:a. Modelling:To comprehend the architectural plan provided by the architect and look-out for the key information from the drawings.Import the architectural floor plan (provided…

    calendar

    03 Dec 2024 06:09 AM IST

    • ETABS
    • Structural Analysis
    Read more

    Project 2 - MODELLING, ANALYSIS & DESIGN OF COMPOSITE STUCTURES IN COMFLOR & ETABS

    Objective:

    Aim:To analyse and to design the composite high rise building using ETABS. And to design the composite deck profile using Comflor software. Procedure:Following  for composite and design:Architectural plan study & Column shear wall position markingSteel beam alignment marking (considering approximate deck…

    calendar

    02 Dec 2024 03:05 AM IST

    • ETABS
    Read more

    Modelling of 25 storey building with the specified properties using ETABS

    Objective:

    Aim: To model and analyse a 25 storey building with given specifications and to cross check the parameters as per IS 1893 provisions. Procedure: Open the ETABS software. Click the file menu and choose to create a new model option. After choosing a new model a dialogue box will appear as model intialization. Choose the…

    calendar

    07 Jul 2024 05:44 AM IST

    • ETABS
    Read more

    Project 2_Analyze and Design the RC office building as per IS standard code in TEKLA STRUCTURAL DESIGNER

    Objective:

      Develop general arrangement for the RC office building. Analyze and design the building as per IS standard code in TEKLA STRUCTURAL DESIGNER. Refer the attached plan and elevation. The building to be designed for dead, live, wind and seismic loading. Report of each member to be generated and extract drawings for structural…

    calendar

    07 Oct 2023 01:08 PM IST

    • DESIGN
    Read more

    Schedule a counselling session

    Please enter your name
    Please enter a valid email
    Please enter a valid number

    Related Courses

    coursecard

    Design loads considered on bridges

    Recently launched

    10 Hours of Content

    coursecard

    Design of Steel Superstructure in Bridges

    Recently launched

    16 Hours of Content

    coursecard

    Design for Manufacturability (DFM)

    Recently launched

    11 Hours of Content

    coursecard

    CATIA for Medical Product Design

    Recently launched

    5 Hours of Content

    coursecardcoursetype

    Accelerated Career Program in Embedded Systems (On-Campus) Courseware Partner: IT-ITes SSC nasscom

    Recently launched

    0 Hours of Content

    Schedule a counselling session

    Please enter your name
    Please enter a valid email
    Please enter a valid number

                Do You Want To Showcase Your Technical Skills?
                Sign-Up for our projects.